Adj Pipe (270mm To 375mm) ICS25 – 5000

Adj Pipe (270mm To 375mm) ICS25 – 5000

ICS 5000 is a multi-functional twin wall insulated venting system, which is suitable for internal and external use on a wide range of engineering, combustion and process equipment, including heating appliances, diesel generators, CHP systems and service ducting.

ICS 5000 comes with a high quality specification as standard with a 316L Grade Stainless steel liner, high performance mineral blanket insulation and a bright annealed 304 Grade stainless steel outer case.

Both liner and outer case have a continuous seam welded joint and each flue gas bearing component has a uniquely profiled spigot and socket joint with bevelled end forms to ensure ease of installation whilst ensuring the joint meets H1 performance criteria at 5000 Pa.

The thermal insulation blanket ensures continuous insulation over the entire effective length of the liner, ensuring fast priming to normal operating temperatures, whilst maintaining low external surface temperatures.

SKU: Adj Pipe (270mm To 375mm) ICS25 - 5000 Category: Tags: , , ,

Available Options:

Description

PRODUCT FEATURES

  • Engineered spigot and socket joint
  • Pronounced lead in edge
  • Quick and easy assembly
  • Pressure gasket on outer case protected by insulation
  • Continuous insulation avoids thermal bridging
  • Inner liner free to expand and contract
  • No requirement for expansion joints
  • Lightweight
  • No onsite welding or cutting required

Schiedel Isokern Garden Fireplace Installation Guide

Thinking about transforming your outdoor living space with a premium volcanic pumice fireplace or outdoor kitchen? To help you prepare for a seamless installation, we’ve compiled the answers to the most common questions regarding safety clearances, UK planning laws, and environmental regulations.

Structural & Safety Clearances

Can I build my garden fireplace directly onto my timber decking?

No. Due to the substantial structural weight of these premium volcanic pumice packages—which range from 460kg up to 1,490kg fully built—they must never be placed on timber decking.

Instead, they require a flat, solid foundation. We strictly recommend a minimum 100mm thick reinforced concrete base to guarantee the completed structure won’t sink or slant over time.

How close can the fireplace be placed to wooden fencing or a pergola?

Because volcanic pumice is a highly effective, natural insulator, the exterior of the fireplace remains safe to touch. However, a precise buffer zone must be maintained between the structure and any combustible materials:

  • The Hale Outdoor Kitchen: Requires a minimum clearance of 100mm.
  • The Kingham & Standalone Fireplaces (500, 950, 1200 Models): Require a minimum clearance of 75mm.

I want to position the chimney near or through a pergola roof. How high should it go?

The chimney flue must completely clear the height of your pergola canopy to ensure exhaust smoke and sparks disperse safely away from your seating area.

If your design requires extra height to clear an overhanging beam line safely, additional chimney blocks can be purchased separately and added to the vertical stack during assembly. We also highly recommend adding a Rain Cap / Wave canopy to maintain a reliable upward draft and block weather down-drafts.

UK Planning Permission & Boundary Rules

Do I need formal Planning Permission from my local council to install a garden fire?

For the vast majority of residential homes, permanent brick or stone barbecues and outdoor fireplaces fall under Permitted Development rights (similar to garden outbuildings or enclosures). This means they do not require a formal planning application, provided your project meets specific layout criteria.

How close to my neighbor’s boundary line or fence can I build the fireplace?

This depends entirely on the total height of your completed structure (including the chimney capping):

  • Structures up to 2.5m tall: Can be positioned as close to your boundary fence or wall as you like (though we recommend a small gap to make rendering the exterior easier).
  • Structures taller than 2.5m: The entire unit must be shifted forward into your property line so that it sits more than 2 metres away from any boundary line or fence.

What are the absolute height limits if I move it more than 2 metres away from the boundary?

Once your fireplace is positioned safely past the 2-metre boundary zone, your Permitted Development allowances increase:

  • Your structure can go up to a maximum height of 3 metres for standard mono-pitch or custom flat profiles.
  • It can go up to a maximum height of 4 metres only if the structure features a dual-pitched (apex/A-frame) roof line.

Note: If your space is restricted and you cannot move a chimney taller than 2.5m at least 2 metres away from a boundary, you must submit a formal Householder Planning Application to your local council before starting construction.

Are there any extra restrictions if my fireplace is completely freestanding?

Yes. If you plan to install your garden fireplace as a standalone, freestanding unit (rather than building it flush against a solid masonry wall or as part of a fully supported outdoor kitchen layout), you must carefully consider the maximum height for wind safety:

  • Standard Kit Height: Our standard packaged kits are completely load-bearing and fully safety-tested to be freestanding at their delivered heights.
  • Adding Extra Chimney Blocks: While you can easily purchase extra chimney blocks to increase the height of your flue, we strongly advise against extending a freestanding chimney beyond 3 metres in total height without a professional structural review.
  • When to consult an expert: If your property is located in an exceptionally exposed or high-wind area (such as a coastal zone or an elevated hillside), or if your custom design calls for a highly extended freestanding chimney flue, you should consult a qualified structural engineer before building. They will assess your local wind load factors and advise if your specific site requires a deeper concrete foundation pad or specialized internal structural reinforcement.

Are there any other garden layout rules I need to worry about?

  1. No Front Yards: You cannot construct a permanent garden fireplace or structure on land forward of the front facade (principal elevation) of your home. It must be situated to the side or rear.
  2. The 50% Rule: The space occupied by the fireplace, outdoor kitchen modules, and any existing sheds/outbuildings must not collectively take up more than 50% of the total land area surrounding your original house.
  3. Designated Land & Listed Buildings: If your home is legally a Listed Building or sits within a Conservation Area, National Park, or Area of Outstanding Natural Beauty (AONB), permitted development rights are typically restricted or removed. You will need to check with your council before starting any stonework.

Environmental & Smoke Regulations

Can I use my garden fireplace if I live in a designated UK Smoke Control Area?

Yes. While the UK Clean Air Act regulates chimney smoke inside urban areas, unroofed outdoor garden fireplaces and barbecues are broadly exempt from domestic indoor chimney restrictions. However, you can still face local enforcement if your fireplace creates what the law defines as a “Statutory Nuisance.”

What is a “Statutory Nuisance” and how do I avoid it?

Under Section 79 of the Environmental Protection Act, if smoke, ash, or persistent fumes from your garden fire regularly blow directly into a neighbor’s property—preventing them from opening their windows, sitting outside, or hanging out laundry—the local council can issue an Abatement Notice.

To avoid this, always position your fireplace where prevailing winds won’t push smoke directly toward neighboring windows, and extend your chimney height if necessary to discharge smoke cleanly upwards.

What fuels am I legally allowed to burn?

To ensure a clean, efficient burn, you should strictly use clean, dry, and seasoned wood logs—ideally labeled with the Woodsure “Ready to Burn” logo, which certifies a moisture content below 25%.

Never Burn: Treated or painted waste wood, old pallets, plastic, or household rubbish. Burning these materials releases volatile, toxic chemicals into the air, creates heavy dark smoke, and leads to an immediate buildup of corrosive tar within your chimney structure.

Schiedel is the first European chimney manufacturer to have performed the tests according to this latest fire resistance standard for chimneys. European standard BS EN 1366-13:2019 “Fire resistance tests for service installations, Part 13: Chimneys” and has reached EI 120 classification for our Double Wall Insulated System Chimney ICS in
a closed scenario (type A) for both vertical and horizontal set-ups.

ICS 5000 is tested and approved in both 25mm and 50mm variants to BS EN 1856-1 as a System Chimney and to BS EN 1856-2 as a connecting flue pipe with the following designations

System Chimney BS EN 1856-1 (TÜV 0036 CPR 9195 027)

ICS25 5000
T600 H1 D V3 L50050 O75* T200 H1 W V2 L50050 O50**

*Distance to Combustibles
*Ø80-Ø300 distance – 75mm
*Ø350-Ø450 distance – 112.5mm
*Ø500- Ø600 distance – 150mm
**Ø80-Ø200 distance – 50mm

ICS50 5000
T600 H1 D V3 L50050 O25*

*Distance to Combustibles

*Ø80-Ø300 distance – 25mm
*Ø350-Ø450 distance – 37.5mm
*Ø500- Ø600 distance – 50mm

Connecting Flue Pipe BS EN 1856-2 (TÜV 0036 CPR 9195 038)
T600 H1 D V3 L50050 O100 M

Connecting Flue Pipe BS EN 1856-2 (TÜV 0036 CPR 9195 036)
T600 H1 D V3 L50050 O100 M

EI 120 Fire rating to BS EN 1366-13 Chimneys
ICS25 5000 and ICS50 5000: Horizontal and Vertical

Corrosion testing on Gas, Oil, Solid Fuel (TÜV 0036 CPR 9195 027)
Gastec, MPA,TÜV

ICS 5000 brochure

ICS 5000 installation instructions

Click here to view Certificates and Declarations of Performance