Gather Unit – Prima Plus

Gather Unit – Prima Plus

Used when lining a masonry chimney to seal the fireplace throat

  • Suitable for gas class 1 fires
SKU: Gather Unit - Prima Plus Categories: , Tags: , , , ,

Available Options:

Description

Prima Plus is a high quality 316L stainless steel single wall flue system with a wall thickness of 0.6mm.

It is designed for use on gas and oil burning stoves and boilers with continuous operating temperatures up to 450°C and short firing up to 600°C. With the addition of a gasket to the joint, Prima Plus is designed for condensing gas and oil appliances with positive pressures up to 200Pa, continuous operating temperatures up to 160°C and short firing up to 200°C.

There are three possible applications:

  1. Connecting Flue Pipe – Prima Plus may be used as the connecting flue pipe between an appliance and the main chimney system. Where used in a horizontal run there must be a fall of at least 3° to allow evacuation of condensates.
  2. Chimney Liner – Prima Plus may be used as an alternative to flexible stainless steel liners in order to re-line an existing chimney.
  3. System Chimney – Prima Plus may be used as a system chimney internally, if installed inside a suitable shaft or externally on runs of up to 3m.

Prima Plus is designed for use on solid fuel, gas and oil burning appliances with continuous operating temperatures of up to 600°C. With the addition of a lip seal gasket to the joint, Prima Plus may be adapted for use on condensing gas and oil appliances with positive pressure of up to 200Pa and continuous operating temperatures of up to 200°C.

For larger commercial and industrial applications of Prima Plus in diameters 350-700mm, please contact us.

Prima Plus Prima Plus with Lip Seal
Fuel Gas, Oil, Wood, Solid Fuel Gas, Oil
Continuous Firing
(Connecting Flue Pipe & Chimney Liner)
600ËšC (T600) 200ËšC (T200)
Continuous Firing (System Chimney) 450ËšC (T450) 200ËšC (T200)
Soot Fire Restistance Yes (G) No (O)
Mode of Operation N1 P1
Pressure Rating 40Pa 200Pa
Wall Thickness 0.6mm
Material 316L : 1.4404 : X2CrNiMo 17-12-2

 

Schiedel Isokern Garden Fireplace Installation Guide

Thinking about transforming your outdoor living space with a premium volcanic pumice fireplace or outdoor kitchen? To help you prepare for a seamless installation, we’ve compiled the answers to the most common questions regarding safety clearances, UK planning laws, and environmental regulations.

Structural & Safety Clearances

Can I build my garden fireplace directly onto my timber decking?

No. Due to the substantial structural weight of these premium volcanic pumice packages—which range from 460kg up to 1,490kg fully built—they must never be placed on timber decking.

Instead, they require a flat, solid foundation. We strictly recommend a minimum 100mm thick reinforced concrete base to guarantee the completed structure won’t sink or slant over time.

How close can the fireplace be placed to wooden fencing or a pergola?

Because volcanic pumice is a highly effective, natural insulator, the exterior of the fireplace remains safe to touch. However, a precise buffer zone must be maintained between the structure and any combustible materials:

  • The Hale Outdoor Kitchen: Requires a minimum clearance of 100mm.
  • The Kingham & Standalone Fireplaces (500, 950, 1200 Models): Require a minimum clearance of 75mm.

I want to position the chimney near or through a pergola roof. How high should it go?

The chimney flue must completely clear the height of your pergola canopy to ensure exhaust smoke and sparks disperse safely away from your seating area.

If your design requires extra height to clear an overhanging beam line safely, additional chimney blocks can be purchased separately and added to the vertical stack during assembly. We also highly recommend adding a Rain Cap / Wave canopy to maintain a reliable upward draft and block weather down-drafts.

UK Planning Permission & Boundary Rules

Do I need formal Planning Permission from my local council to install a garden fire?

For the vast majority of residential homes, permanent brick or stone barbecues and outdoor fireplaces fall under Permitted Development rights (similar to garden outbuildings or enclosures). This means they do not require a formal planning application, provided your project meets specific layout criteria.

How close to my neighbor’s boundary line or fence can I build the fireplace?

This depends entirely on the total height of your completed structure (including the chimney capping):

  • Structures up to 2.5m tall: Can be positioned as close to your boundary fence or wall as you like (though we recommend a small gap to make rendering the exterior easier).
  • Structures taller than 2.5m: The entire unit must be shifted forward into your property line so that it sits more than 2 metres away from any boundary line or fence.

What are the absolute height limits if I move it more than 2 metres away from the boundary?

Once your fireplace is positioned safely past the 2-metre boundary zone, your Permitted Development allowances increase:

  • Your structure can go up to a maximum height of 3 metres for standard mono-pitch or custom flat profiles.
  • It can go up to a maximum height of 4 metres only if the structure features a dual-pitched (apex/A-frame) roof line.

Note: If your space is restricted and you cannot move a chimney taller than 2.5m at least 2 metres away from a boundary, you must submit a formal Householder Planning Application to your local council before starting construction.

Are there any extra restrictions if my fireplace is completely freestanding?

Yes. If you plan to install your garden fireplace as a standalone, freestanding unit (rather than building it flush against a solid masonry wall or as part of a fully supported outdoor kitchen layout), you must carefully consider the maximum height for wind safety:

  • Standard Kit Height: Our standard packaged kits are completely load-bearing and fully safety-tested to be freestanding at their delivered heights.
  • Adding Extra Chimney Blocks: While you can easily purchase extra chimney blocks to increase the height of your flue, we strongly advise against extending a freestanding chimney beyond 3 metres in total height without a professional structural review.
  • When to consult an expert: If your property is located in an exceptionally exposed or high-wind area (such as a coastal zone or an elevated hillside), or if your custom design calls for a highly extended freestanding chimney flue, you should consult a qualified structural engineer before building. They will assess your local wind load factors and advise if your specific site requires a deeper concrete foundation pad or specialized internal structural reinforcement.

Are there any other garden layout rules I need to worry about?

  1. No Front Yards: You cannot construct a permanent garden fireplace or structure on land forward of the front facade (principal elevation) of your home. It must be situated to the side or rear.
  2. The 50% Rule: The space occupied by the fireplace, outdoor kitchen modules, and any existing sheds/outbuildings must not collectively take up more than 50% of the total land area surrounding your original house.
  3. Designated Land & Listed Buildings: If your home is legally a Listed Building or sits within a Conservation Area, National Park, or Area of Outstanding Natural Beauty (AONB), permitted development rights are typically restricted or removed. You will need to check with your council before starting any stonework.

Environmental & Smoke Regulations

Can I use my garden fireplace if I live in a designated UK Smoke Control Area?

Yes. While the UK Clean Air Act regulates chimney smoke inside urban areas, unroofed outdoor garden fireplaces and barbecues are broadly exempt from domestic indoor chimney restrictions. However, you can still face local enforcement if your fireplace creates what the law defines as a “Statutory Nuisance.”

What is a “Statutory Nuisance” and how do I avoid it?

Under Section 79 of the Environmental Protection Act, if smoke, ash, or persistent fumes from your garden fire regularly blow directly into a neighbor’s property—preventing them from opening their windows, sitting outside, or hanging out laundry—the local council can issue an Abatement Notice.

To avoid this, always position your fireplace where prevailing winds won’t push smoke directly toward neighboring windows, and extend your chimney height if necessary to discharge smoke cleanly upwards.

What fuels am I legally allowed to burn?

To ensure a clean, efficient burn, you should strictly use clean, dry, and seasoned wood logs—ideally labeled with the Woodsure “Ready to Burn” logo, which certifies a moisture content below 25%.

Never Burn: Treated or painted waste wood, old pallets, plastic, or household rubbish. Burning these materials releases volatile, toxic chemicals into the air, creates heavy dark smoke, and leads to an immediate buildup of corrosive tar within your chimney structure.

For stove and chimney installers – whenever you register an installation with our easy to use, online guarantee registration portal, you will now accrue points based on the number of installations. So click here to start and register your installations, taking full advantage of our Lifetime Guarantee on Flex and ICID, as well as guarantees on all our other ranges, and to start earning points 🙂

Prima Plus brochure

Prima Plus installation instructions

Click here to view Certificates and Declarations of Performance

Prima Plus is CE Certified for the following applications:-

Connecting Flue Pipe -EN1856-2TÜV 0036 CPR 9195 017
Chimney Liner – EN1856-2 TÜV 0036 CPR 9195 019
System Chimney – EN1856-1 TÜV 0036 CPR 9195 018

CE Designations are as follows:-

Connecting Flue Pipe

High Temperature Applications T600 N1 W V2 L50060 G400 M*
Low Temperature Applications T200 P1 W V2 L50060 O200 M* and  T200 N1 W V2 L50060 O200 M*

Chimney Liner

High Temperature Applications  T600 N1 W V2 L50060 G
Low Temperature Applications T200 P1 W V2 L50060 O

System Chimney

High Temperature Applications T450 N1 W V2 L50060 G50** and T450 N1 D V2 L50060 G50***
Low Temperature Applications T200 P1 W V2 L50060 O200

* M stands for measured distance to combustibles on a connecting flue pipe application in the range of diameters Ø150-Ø200
For other diameters in the range the following distances should be used: Ø80-125 =375mm, Ø130 = 390mm
** Used internally inside a non combustible shaft
*** Insulated and used internally inside a suitable enclosure

 

FREE Access to advanced CAD modelling files.

Please visit our external BIM (Business Information Modelling) for access to advanced modelling files in a number of formats. Please note that you will have to register and login for access to the files.

Click here to access our BIM files. 

A useful app with guides on installation as well as step-by-step video guides.

This app was designed for installers to have all the information they require in a few quick clicks. This makes it easier for installers rather than having to carry paperwork during the installation process with video breakdowns of each stage of the installation process.

Download the iPhone and iPad version in the App Store and Android version in the Google Play Store.

app store  e google play  e