USR Rosette smooth

USR Rosette smooth

This component is part of the US flue system. US is a concentric system suitable for high temperature, non-condensing applications with flue gases in negative pressure.

With the US range, both wall and roof terminals are available. The system has easy assembly with lightweight elements. The wide product range offers solutions for virtually all situations  and it is tested in combination with many appliances according to EN 613.

SKU: US system ROSETTE_SMOOTH Categories: ,

Available Options:

Description

The US system is a modular concentric balanced flue system, made of stainless steel which combines air inlet and flue.

US is suitable for high temperature, non-condensing applications with flue gases in negative pressure. It can be applied on all types of balanced flue gas-fired stoves (class C11 and (231). Advantages include:

  • Appliance adaptors manufactured on specification.
  • Both wall and roof terminals available.
  • Easy assembly with lightweight elements.
  • Wide product range offers solutions for virtually all situations.
  • Tested in combination with many appliances according to EN 613.

 

Technical characteristics
Application Balanced flue
Operating mode Dry
Pressure Negative pressure
Max. working pressure 0 Pa
Operating temperature 600°O
Max. temperature allowed 600°C
Inner wall material AISI 304/EN 1.4301
thickness 0.4 mm
Outer wall material AISI 304/EN 1.4301
thickness 0.4 mm
Fuel type Gas
Chimney diameter
Inner diameter (mm) 100 130
Outer diameter (mm) 150 200
Cross section (cm2) 79 133
Weight (±kg/m) 2.5 4.0
CE approved
EN 1856-1: T450 N1 D V2 L20040 050, T450 N1 D V2 L20040 050
EN 1856-2: T450 N1 D V2 L20040 050, T450 N1 D V2 L20040 050

 

US is CE approved to EN 1856-1: T450 N1 D V2 L20040 050, T450 N1 D V2 L20040 050
US is CE approved to EN 1856-2: T450 N1 D V2 L20040 050, T450 N1 D V2 L20040 050

Technical characteristics
Application Balanced flue
Operating mode Dry
Pressure Negative pressure
Max. working pressure 0 Pa
Operating temperature 600°O
Max. temperature allowed 600°C
Inner wall material AISI 304/EN 1.4301
thickness 0.4 mm
Outer wall material AISI 304/EN 1.4301
thickness 0.4 mm
Fuel type Gas
Chimney diameter
Inner diameter (mm) 100 130
Outer diameter (mm) 150 200
Cross section (cm2) 79 133
Weight (±kg/m) 2.5 4.0