Schiedel is the first European chimney manufacturer to have performed the tests according to this latest fire resistance standard for chimneys. European standard BS EN 1366-13:2019 โFire resistance tests for service installations, Part 13: Chimneysโ and has reached EI 120 classification for our Double Wall Insulated System Chimney ICS in
a closed scenario (type A) for both vertical and horizontal set-ups.
ICS 5000 is tested and approved in both 25mm and 50mm variants to BS EN 1856-1 as a System Chimney and to BS EN 1856-2 as a connecting flue pipe with the following designations
System Chimney BS EN 1856-1 (TรV 0036 CPR 9195 027)
ICS25 5000
T600 H1 D V3 L50050 O75* T200 H1 W V2 L50050 O50**
*Distance to Combustibles
*ร80-ร300 distance – 75mm
*ร350-ร450 distance – 112.5mm
*ร500- ร600 distance – 150mm
**ร80-ร200 distance – 50mm
ICS50 5000
T600 H1 D V3 L50050 O25*
*Distance to Combustibles
*ร80-ร300 distance – 25mm
*ร350-ร450 distance – 37.5mm
*ร500- ร600 distance – 50mm
Connecting Flue Pipe BS EN 1856-2 (TรV 0036 CPR 9195 038)
T600 H1 D V3 L50050 O100 M
Connecting Flue Pipe BS EN 1856-2 (TรV 0036 CPR 9195 036)
T600 H1 D V3 L50050 O100 M
EI 120 Fire rating to BS EN 1366-13 Chimneys
ICS25 5000 and ICS50 5000: Horizontal and Vertical
Corrosion testing on Gas, Oil, Solid Fuel (TรV 0036 CPR 9195 027)
Gastec, MPA,TรV